| Sign In | Join Free | My infospaceinc.com |
|
Price : USD 400/Unit
Packaging Details : original packing
Current Duty Basis : Below 10 Percent ED; Maximum 10 Seconds
Model Number : CDBR-4045B
Minimum Connectable Resistance : 13.4 Ohm
Supply Ability : 10Units per Month
Voltage Class : 380 to 460 VAC
Peak Current : 60 A Peak
Payment Terms : D/A, D/P, T/T, Western Union, MoneyGram,
DC Bus Operating Range : 460 to 800 VDC Peak
Delivery Time : 3-5Days
Product Type : Dynamic Braking Transistor Unit
Brand Name : YASKAWA
Heat Loss : 59 W
Protective Configuration : Wall-Mounted Enclosed Type
Rated Current : 18 A
MOQ : 1
Dimensions : 150 x 120 x 157 mm
Braking Start Voltage Settings : 630 / 660 / 690 / 730 / 760 VDC
Place of Origin : USA
Model : CDBR-4045B
External Braking Resistor : Required
The Yaskawa CDBR-4045B is a previous-generation 400 V-class dynamic braking transistor unit used with industrial AC drives. It provides a rated discharge current of 18 A and a maximum peak discharge current of 60 A.
The unit detects DC bus voltage during deceleration and switches regenerated energy into an external braking resistor. It is not a braking resistor and cannot operate as a complete braking system without a correctly selected resistor and thermal-protection circuit.
| Manufacturer | Yaskawa Electric |
| Series | CDBR-B |
| Model | CDBR-4045B |
| Product Type | Dynamic Braking Transistor Unit |
| Product Generation | Previous Generation |
| AC Drive Voltage Range | 380 to 460 VAC |
| DC Bus Range | 460 to 800 VDC Peak |
| Rated Discharge Current | 18 A |
| Maximum Discharge Current | 60 A Peak |
| Duty Reference | Below 10 Percent ED; Maximum 10 Seconds |
| Braking Start Settings | 630 / 660 / 690 / 730 / 760 VDC |
| Reference Motor Output | 60 HP / 45 kW with One Unit in Legacy Selection Table |
| Heat Loss | 59 W |
| Protective Configuration | Wall-Mounted Enclosed Type |
| Approximate Dimensions | 150 x 140 x 138.5 mm |
| Current Upgrade Candidate | CDBR-40450D |
The CDBR-4045B was used with several previous-generation Yaskawa industrial drive families. The exact compatible drive cannot be identified from voltage class alone. Confirm the complete inverter model, DC bus terminals, braking-resistor arrangement and control circuit.
Typical legacy applications include cranes, hoists, conveyors, winders, machine tools, centrifuges and production machinery requiring shorter deceleration times.
Before replacing an existing CDBR-4045B, verify the supply-voltage selection connector, master or slave setting, power terminals, control terminals, external resistor resistance and thermal-protection circuit.
The legacy selection table associates one CDBR-4045B with a 60 HP or 45 kW application under defined braking conditions. This is a reference combination rather than a universal maximum motor rating.
CDBR-40450D is the corresponding current 18 Arms D-series model. The changeover is not automatically plug-and-play because the B and D units differ in enclosure depth, width, mounting arrangement and terminal configuration.
Related models include CDBR-4030B, CDBR-4090B, CDBR-4220B and the newer CDBR-40450D or CDBR-4045D.
Please provide photographs of the complete nameplate, installed drive model, resistor model, wiring terminals and mounting area. Availability and condition should be confirmed for each quotation because this is a previous-generation product.
|
|