| Sign In | Join Free | My infospaceinc.com |
|
Pressuretype : Gauge or Absolute
Model Number : PT4624-15M-6/18-SIL2
Productname : Dynisco Melt Pressure Transducer
Brand Name : Dynisco
Accuracy : ±0.25% Full Scale
Supply Ability : 10 Units per Month
Responsetime : Less than 1 ms
Price : USD 1000 - 1500 / Unit
Mountingtype : Flush or Flush with diaphragm
Delivery Time : 7-14 Days
Electricalconnection : Integral Cable or Connector
MOQ : 1 unit
Packaging Details : Anti-static Bag + Carton Box + Foam Protection
Type : Pressure Transducer
Certification : CE
Application : Plastic extrusion, injection molding
Place of Origin : USA
The Dynisco PT4624-15M-6/18-SIL2 is a high-range two-wire melt-pressure transmitter with a nominal 0 to 15,000 psi measuring range and 4-20 mA output. It is intended for demanding polymer processes where pressure must be transmitted over an industrial current loop to the control system.
The rigid-stem and flexible-capillary configuration allows the electronics housing to be positioned away from the hot process connection. The high range and SIL2 designation require careful verification of pressure scaling, safety documentation and mechanical installation.
| Complete Model | PT4624-15M-6/18-SIL2 |
| Pressure Range | 0 to 15,000 psi |
| Output Signal | Two-wire 4-20 mA |
| Process Thread | 1/2-20 UNF |
| Mechanical Design | Rigid stem with flexible capillary |
| Safety Configuration | SIL2 device configuration |
| Maximum Diaphragm Temperature | Up to 400 degrees C |
A 15,000 psi transmitter must be paired with an analog input and software scale configured for that full range. Selecting an unnecessarily high range can reduce useful resolution, while selecting too low a range can expose the diaphragm to overload. Actual operating and transient pressures should be reviewed.
Confirm pressure range, system maximum pressure, 4-20 mA scaling, supply voltage, loop load, process connection, stem arrangement, connector pinout and SIL documentation. The complete safety loop must be validated by the responsible machine or process engineer.
Provide the nameplate, process-pressure data, PLC input specification and required safety documentation before quotation.
|
|
Dynisco PT4624-15M-6/18-SIL2 High-Range Melt Pressure Transmitter Images |